- 40 C Sensor Junction Blocks

Results: 36
Select Image Part # Mfr. Description Datasheet Availability Pricing (INR) Filter the results in the table by unit price based on your quantity. Qty. RoHS Sensor Connector Type Number of Ports Home Run Connector Type Home Run Number of Pins Cable Length Cable Diameter Voltage Rating Current Rating Coding Housing Material IP Rating Series
Banner Engineering Sensor Junction Blocks 4-Port Molded Junction Box; 2 Female 4-pin M12 A-Code, 1 Female 5-pin M12 L-Code Ports; Male 5-pin M12 L-Code Integral Homerun; Parallel Wiring on Pins 1 & 3, H Configuration 12In Stock
6Expected 26-05-2026
Min.: 1
Mult.: 1

M12 4 63 VDC 4 A, 16 A A Coded, L Coded Thermoplastic Polyurethane (TPU) IP65, IP67, IP68 R50
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 2 Meter Flying Lead Homerun; Dual Signal Ports
3In Stock
Min.: 1
Mult.: 1

M12 8 M23 19 2 m 30 VDC 8 A Thermoplastic Polyurethane (TPU) R95
Banner Engineering Sensor Junction Blocks R50 3-port L-Code Junction Block; 2 Female 5-pin M12 L-Code Ports; Male 5-pin M12 L-Code Integral Homerun; Parallel Wiring, H Configuration 3In Stock
Min.: 1
Mult.: 1
M12 3 M12 5 60 VDC 16 A L Coded Thermoplastic Polyurethane (TPU) IP65, IP67, IP68 R50
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 5 Meter Flying Lead Homerun; Dual Signal Ports
3In Stock
Min.: 1
Mult.: 1
M12 8 M23 19 5 m 30 VDC 8 A Thermoplastic Polyurethane (TPU) R95
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 PNP Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 2 Meter Flying Lead Homerun; Dual Signal Ports w_ PNP LEDs
2In Stock
Min.: 1
Mult.: 1

M12 8 M23 19 2 m 30 VDC 8 A Thermoplastic Polyurethane (TPU) R95
Lumberg Automation Sensor Junction Blocks LioN-Safety 8/4-F-DI 4-F-DO 2-IOLM M12 PROFInet / PROFIsafe , M12 L-coded Power Supply, Metal 60mm, IoT Protocols (OPC UA, MQTT, CoAP, REST)
1In Stock
Min.: 1
Mult.: 1

IP65, IP67, IP69K LioN-Safety
Lumberg Automation Sensor Junction Blocks LioN-Safety 8/4-F-DI 4-F-DO 2-IOLM M12 EtherNet/IP / CIP Safety , M12 L-coded Power Supply, Metal 60mm, IoT Protocols (OPC UA, MQTT, CoAP, REST)
1In Stock
Min.: 1
Mult.: 1

IP65, IP67, IP69K LioN-Safety
Advantech Sensor Junction Blocks Rugged IP67 Machine Mount IoT Remote I/O 3In Stock
5Expected 16-06-2026
Min.: 1
Mult.: 1

M12 24 V 12 A IP67 ADAM-200PN
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 1 Meter Flying Lead Homerun; Dual Signal Ports 6In Stock
Min.: 1
Mult.: 1

M12 8 Port M23 19 Pin 1 m 9.2 mm 30 V 8 A Thermoplastic Polyurethane (TPU) R95
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 PNP Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 1 Meter Flying Lead Homerun; Dual Signal Ports w_ PNP LEDs 3In Stock
Min.: 1
Mult.: 1

M12 8 Port M23 19 Pin 1 m 9.2 mm 30 V 8 A Thermoplastic Polyurethane (TPU) R95
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 PNP Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 0.3M Male M23 19-pin Homerun; Dual Signal Ports w_ PNP LEDs 3In Stock
Min.: 1
Mult.: 1

M12 8 Port M23 19 Pin 0.3 m 9.2 mm 30 V 8 A Thermoplastic Polyurethane (TPU) R95
Banner Engineering Sensor Junction Blocks 4-Port Molded Junction Box; 4 Female 5-pin M12 Ports; Male 5-pin M12 Integral Homerun; Parallel Wiring 60In Stock
Min.: 1
Mult.: 1
M12 4 Port M12 5 Pin 60 VDC 4 A Thermoplastic Polyurethane (TPU) R50

Phoenix Contact Sensor Junction Blocks SACB- 4/3-L- 5 0PUR-M8 HD 8In Stock
Min.: 1
Mult.: 1
M8 4 Port Pre-wired Cable 3 Pin 5 m 6.8 mm 24 VDC 6 A A Coded Polybutylene Terephthalate (PBT) IP67
Banner Engineering Sensor Junction Blocks 8-Port Molded Junction Box; 8 Female 5-pin M12 Ports; Male 5-pin M12 Integral Homerun; Parallel Wiring 10In Stock
Min.: 1
Mult.: 1
M12 8 Port M12 5 Pin 60 VDC 4 A Thermoplastic Polyurethane (TPU) R95
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 Signals and M23 Homerun; 8 Female 5-pin M12 Ports; 0.3 Meter 19-pin M23 Homerun; Dual Signal Ports
5Expected 21-05-2026
Min.: 1
Mult.: 1

M12 8 Port M23 19 Pin 0.3 m 9.2 mm 30 V 8 A Thermoplastic Polyurethane (TPU) R95
Lumberg Automation Sensor Junction Blocks LioN-Safety 16/8-F-DI M12 PROFInet / PROFIsafe , M12 L-coded Power Supply, Metal 60mm, IoT Protocols (OPC UA, MQTT, CoAP, REST)
Non-Stocked Lead-Time 4 Weeks
Min.: 1
Mult.: 1

IP65, IP67, IP69K LioN-Safety
Phoenix Contact Sensor Junction Blocks SACB- 8/3-L- 5 0PUR-M8 HD Non-Stocked Lead-Time 8 Weeks
Min.: 1
Mult.: 1
M8 8 Port Pre-wired Cable 3 Pin 5 m 7.9 mm 24 VDC 6 A A Coded Polybutylene Terephthalate (PBT) IP67
Banner Engineering Sensor Junction Blocks R50 3-port L-Code Junction Block; 2 Female 5-pin M12 L-Code Ports; Male 5-pin M12 L-Code Integral Homerun; Parallel Wiring, T configuration Non-Stocked Lead-Time 4 Weeks
Min.: 1
Mult.: 1
2 Port M12 5 Pin 60 V 16 A L-Code Thermoplastic Polyurethane (TPU) IP65, IP67, IP68
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 8-pin M12 Male Connector; 6 Female 5-pin M12 Ports; Male 8-pin M12 Pigtail Homerun; Muting Sensor Option for S4B Non-Stocked Lead-Time 4 Weeks
Min.: 1
Mult.: 1
M12 6 Port M12 8 Pin 30 V 2 A Thermoplastic Polyurethane (TPU) IP67 R95
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 PNP Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 5 Meter Flying Lead Homerun; Dual Signal Ports w_ PNP LEDs
Non-Stocked Lead-Time 3 Weeks
Min.: 1
Mult.: 1
8 Port M12 19 Pin 5 m 30 V 8 A Thermoplastic Polyurethane (TPU)
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 10 Meter Flying Lead Homerun; Dual Signal Ports
Non-Stocked Lead-Time 3 Weeks
Min.: 1
Mult.: 1

M12 8 M23 19 10 m 30 VDC 8 A Thermoplastic Polyurethane (TPU) R95
Banner Engineering Sensor Junction Blocks R95 Molded Junction Box with 16 PNP Signals and Cable Homerun; 8 Female 5-pin M12 Ports; 10 Meter Flying Lead Homerun; Dual Signal Ports w_ PNP LEDs
Non-Stocked Lead-Time 3 Weeks
Min.: 1
Mult.: 1

M12 8 M23 19 10 m 30 VDC 8 A Thermoplastic Polyurethane (TPU) R95
Lumberg Automation Sensor Junction Blocks LioN-Safety 16/8-F-DI M12 EtherNet/IP / CIP Safety , M12 L-coded Power Supply, Metal 60mm, IoT Protocols (OPC UA, MQTT, CoAP, REST)
Non-Stocked
Min.: 1
Mult.: 1

IP65, IP67, IP69K LioN-Safety
Lumberg Automation Sensor Junction Blocks LioN-X 16 DIO Digital with Multiprotocol Non-Stocked
Min.: 1
Mult.: 1

IP65, IP67, IP69K
Lumberg Automation Sensor Junction Blocks LioN-X 16DI Digital with Multiprotocol Non-Stocked
Min.: 1
Mult.: 1

IP65, IP67, IP69K