Push-In Circuit Breakers

Results: 53
Select Image Part # Mfr. Description Datasheet Availability Pricing (INR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Series Product Type Current Rating Voltage Rating AC Voltage Rating DC Number of Poles Minimum Operating Temperature Maximum Operating Temperature Illuminated Packaging
Phoenix Contact Circuit Breakers PTCB E1 24DC/0.63A NO
3In Stock
4Expected 05-10-2026
Min.: 1
Mult.: 1

Circuit Breakers 630 mA 24 VDC 1 Pole - 30 C + 60 C
Phoenix Contact Circuit Breakers TCP 32DC/30A M
8In Stock
100Expected 16-10-2026
Min.: 1
Mult.: 1

Circuit Breakers Thermal 30 A 32 VDC 1 Pole - 40 C + 85 C Non-Illuminated
Phoenix Contact Circuit Breakers PTCB E1 24DC/0.1-0.63A SI-R
25On Order
Min.: 1
Mult.: 1

Circuit Breakers 100 mA to 630 mA 24 VDC 1 Pole - 30 C + 60 C
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 10 A 240 VAC 50 VDC 2 Pole - 30 C + 60 C Non-Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 15 A 240 VAC 50 VDC 2 Pole - 30 C + 60 C Non-Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 15 A 230 VAC 50 VDC 2 Pole - 30 C + 60 C Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked Lead-Time 6 Weeks
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 20 A 230 VAC 50 VDC 2 Pole - 30 C + 60 C Illuminated
E-T-A Circuit Breakers 508, 1P, DM, 24VDC, 1CH, 1A, No Comm
Non-Stocked Lead-Time 6 Weeks
Min.: 1
Mult.: 1

REX12-T Electronic 1 A 24 VDC 1 Pole - 25 C + 60 C Non-Illuminated
Phoenix Contact Circuit Breakers PTCB E1 24DC/0.2A SI-R
Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1

Circuit Breakers 200 mA 24 VDC 1 Pole - 30 C + 60 C
Phoenix Contact Circuit Breakers PTCB E1 24DC/0.2A NO
Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1

Circuit Breakers 100 mA 24 VDC 1 Pole - 30 C + 60 C
Phoenix Contact Circuit Breakers PTCB E1 24DC/0.63A SI-R
Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1

Circuit Breakers 630 mA 24 VDC 1 Pole - 30 C + 60 C
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
Non-Stocked
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 5 A 240 VAC 50 VDC 2 Pole - 30 C + 60 C Non-Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
Non-Stocked
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 5 A 240 VAC 50 VDC 2 Pole - 30 C + 60 C Non-Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
Non-Stocked
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 20 A 240 VAC 50 VDC 2 Pole - 30 C + 60 C Non-Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
Non-Stocked
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 10 A 240 VAC 50 VDC 2 Pole - 30 C + 60 C Non-Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
Non-Stocked
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 15 A 240 VAC 50 VDC 2 Pole - 30 C + 60 C Non-Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
Non-Stocked
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 20 A 240 VAC 50 VDC 2 Pole - 30 C + 60 C Non-Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
Non-Stocked
Min.: 1
Mult.: 1
3120-N Thermal Circuit Breakers Overcurrent Protection 10 A 230 VAC 50 VDC 2 Pole - 30 C + 60 C Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked
Min.: 1
Mult.: 1
3120-N Thermal Circuit Breakers Overcurrent Protection 20 A 230 VAC 50 VDC 2 Pole - 30 C + 60 C Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload prot
Non-Stocked
Min.: 1
Mult.: 1

3120-N Thermal Circuit Breakers Overcurrent Protection 15 A 230 VAC 50 VDC 2 Pole - 30 C + 60 C Illuminated
E-T-A Circuit Breakers The 3120-N thermal circuit breaker/switch combination unites overcurrent protection and the function of an ON/OFF switch within a single component. The trip element is a thermal bimetal. Type 3120-N is ideally suited for overload protection of motors
Non-Stocked
Min.: 1
Mult.: 1
3120-N Thermal Circuit Breakers Overcurrent Protection 10 A 240 VAC 24 VDC 1 Pole - 30 C + 60 C Illuminated
LUTZE / Amphenol Circuit Breakers LOCC-BOX-FB 7-6403 Non-Stocked
Min.: 1
Mult.: 1

LOCC-BOX Electronic Circuit Breakers 40 A 10 VDC to 30 VDC - 25 C + 50 C Illuminated Bulk
LUTZE / Amphenol Circuit Breakers LOCC-BOX-FB 7-6404 Non-Stocked
Min.: 1
Mult.: 1

LOCC-BOX Electronic Circuit Breakers 40 A 10 VDC to 30 VDC - 25 C + 50 C Illuminated Bulk
LUTZE / Amphenol Circuit Breakers LOCC-BOX-M DC12/24VDC, 1-8A, 5 CHARAC.
Non-Stocked
Min.: 1
Mult.: 1

LOCC-BOX Circuit Breakers DC Breaker 8 A 12 VDC, 24 VDC - 25 C + 50 C Illuminated Bulk
Carling Technologies Circuit Breakers MA1B14620AA162J
Non-Stocked
Min.: 1
Mult.: 1

M Hydraulic Magnetic Circuit Breakers Rocker 20 A 125 VAC, 250 VAC 80 VDC 1 Pole - 40 C + 85 C Non-Illuminated